Mostrando 10 resultados de: 11
Filtros aplicados
Subtipo de publicación
Article(11)
Publisher
Analytica Chimica Acta(7)
Journal of Analytical Atomic Spectrometry(2)
Talanta(1)
The Analyst(1)
A time-based flow injection-cold vapor-atomic absorption spectrometry system with on-line microwave sample pre-treatment for the determination of inorganic and total mercury in urine
ArticleAbstract: A time based injection system used in conjunction with cold vapor generation atomic absorption spectPalabras claves:Flow injection, Mercury, On-line microwave digestion, URINEAutores:Bahsas H., Brunetto R., Burguera M., Luis Burguera J., Maximo Gallignani, Petit de Peña Y.Fuentes:googlescopusDetermination of bismuth in biological samples using on-line flow- injection microwave-assisted mineralization and precipitation/dissolution for electrothermal atomic absorption spectrometry
ArticleAbstract: An on-line automated flow injection system with microwave-assisted sample digestion for the electrotPalabras claves:Biological samples, Bismuth, Electrothermal atomic absorption spectrometry, Flow injectionAutores:Burguera M., Carrero P., Luis Burguera J., Maximo Gallignani, Rivas C., Róndon C.Fuentes:googlescopusDetermination of iron and zinc in adipose tissue by on-line microwave-assisted mineralization and flow-injection graphite furnace atomic absorption spectrometry
ArticleAbstract: Flow injection was used to develop an on-line automated focused microwave assisted procedure for thePalabras claves:Adipose, Atomic absorption spectrometry, Flow injection, Iron, Mineralization, ZincAutores:Brunetto R., Burguera M., Carrero P., Luis Burguera J., Maximo Gallignani, Rivas C.Fuentes:googlescopusFlow-injection derivative Fourier transform infrared determination of methyl tert-butyl ether in gasolines
ArticleAbstract: A procedure was developed for the flow-injection Fourier transform (FT) infrared spectrometric deterPalabras claves:Derivative spectroscopy, Flow injection, Gasoline, Infrared spectrometry, Methyl tert-butyl ether.Autores:Garrigues S., Guardia M., Maximo GallignaniFuentes:googlescopusFlow-injection determination of water in organic solvents by near-infrared spectrometry
ArticleAbstract: A flow-injection (FI) procedure was developed for the direct determination of water in organic solvePalabras claves:Dichloromethane, Flow injection, Infrared spectrometry, Isobutyl methyl ketone, Organic solvents, WatersAutores:Garrigues S., Guardia M., Maximo GallignaniFuentes:googlescopusDirect determination of benzene in gasoline by flow-injection Fourier transform infrared spectrometry
ArticleAbstract: A Fourier transform infrared spectrometric procedure for the automated determination of benzene in gPalabras claves:Benzene, Flow injection, Gasoline, Infrared spectrometryAutores:Garrigues S., Guardia M., Maximo GallignaniFuentes:googlescopusOn-line ion exchange for the removal of sulfur anion interference on the determination of manganese in geothermal fluids by flow injection electrothermal atomic absorption spectrometry
ArticleAbstract: An efficient flow injection system with an on-line anion-exchange resin column (Dowex-1) incorporatePalabras claves:Electrothermal atomic absorption spectrometry, Flow injection, Geothermal fluids, manganese, On-line ion exchange, Time-based injectorAutores:Brunetto R., Burguera M., Carrero P., Luis Burguera J., Maximo Gallignani, Rivas C.Fuentes:googlescopusIn vivo sample uptake and on-line measurements of cobalt in whole blood by microwave-assisted mineralization and flow injection electrothermal atomic absorption spectrometry
ArticleAbstract: An on-line automated microwave-assisted mineralization and flow injection system was developed for tPalabras claves:Cobalt, Electrothermal atomic absorption spectrometry, Flow injection, Microwave-oven mineralization, On-line mineralization, Whole bloodAutores:Brunetto R., Burguera M., Carrero P., Luis Burguera J., Maximo Gallignani, Rivas C., Róndon C.Fuentes:googlescopusSimultaneous determination of ortho-, meta- and para-xylene by flow injection-fourier transform infrared spectroscopy
ArticleAbstract: A method has been developed for the direct simultaneous determination of ortho-, meta- and para-xylePalabras claves:Determination of ortho-, meta- and para-xylene, Flow injection, Fourier transform infrared spectroscopy, Simultaneous multicomponent analysisAutores:Garrigues S., Guardia M., Maximo GallignaniFuentes:googlescopusSynthetic zeolites as sorbent material for on-line preconcentration of copper traces and its determination using flame atomic absorption spectrometry
ArticleAbstract: This work assesses for the first time the potential of synthetic zeolites as adsorptive material forPalabras claves:Atomic absorption spectroscopy, Copper, Flow injection, On-line preconcentration, Synthetic zeolitesAutores:Brunetto R., Burguera M., Carrero P., Imbert F.E., López W., Luis Burguera J., Maximo Gallignani, Petit de Peña Y., Róndon C., Wilmer LópezFuentes:googlescopus