Mostrando 8 resultados de: 8
Filtros aplicados
Subtipo de publicación
Article(8)
Publisher
Journal of Arthroplasty(2)
Bone and Joint Journal(1)
International Journal of Medical Robotics and Computer Assisted Surgery(1)
International Orthopaedics(1)
Journal of Biomechanics(1)
Área temáticas
Cirugía y especialidades médicas afines(8)
Medicina y salud(3)
Farmacología y terapéutica(1)
Medicina forense; incidencia de enfermedades(1)
Origen
scopus(8)
In Vitro Kinematic Analysis of Single Axis Radius Posterior-Substituting Total Knee Arthroplasty
ArticleAbstract: This is an experimental study. As current posterior-substituting (PS) total knee arthroplasties havePalabras claves:Force, Kinematics, medial and lateral collateral ligaments, posterior-substituting total knee arthroplastyAutores:Castillo T., Klemt C., Kwon Y.M., Paul Arauz, Peng Y.Fuentes:scopusIn vivo kinematic analysis of patients with robotic-assisted total hip arthroplasty during gait at 1-year follow-up
ArticleAbstract: Background: Suboptimal component positioning has been suggested as an important contributing factorPalabras claves:asymmetry, component positioning, gait, Kinematics, robotic arm–assisted surgery, total hip arthroplastyAutores:Byers A., Desai P., Klemt C., Kwon Y.M., Paul Arauz, Peng Y.Fuentes:scopusIn vivo kinematics of deep lunges and sit-to-stand activities in patients with bicruciate-retaining total knee arthroplasty
ArticleAbstract: Aims The removal of the cruciate ligaments in total knee arthroplasty (TKA) has been suggested as aPalabras claves:Autores:Klemt C., Kwon Y.M., Paul Arauz, Peng Y.Fuentes:scopusIn-vivo analysis of sliding distance and cross-shear in Bi-cruciate retaining total knee arthroplasty
ArticleAbstract: Polyethylene remains the most popular bearing material for total knee arthroplasty (TKA). Despite itPalabras claves:Bi-cruciate retaining total knee arthroplasty, cross-shear, gait, In-vivo kinematics, Sliding distance, WearAutores:An S., Kwon Y.M., Paul Arauz, Peng Y.Fuentes:scopusIn-vivo elongation of anterior and posterior cruciate ligament in bi-cruciate retaining total knee arthroplasty
ArticleAbstract: Anterior and posterior cruciate ligament (ACL and PCL) sacrifice in contemporary total knee arthroplPalabras claves:Anterior cruciate ligament, Bi-cruciate retaining total knee arthroplasty, Fluoroscopy, ligament elongation, Posterior cruciate ligamentAutores:Kwon Y.M., Li G., Liow M.H.L., Paul Arauz, Peng Y., Tsai T.Y.Fuentes:scopusKnee motion symmetry was not restored in patients with unilateral bi-cruciate retaining total knee arthroplasty—in vivo three-dimensional kinematic analysis
ArticleAbstract: Purpose: Although unilateral total knee arthroplasty (TKA) is successful in restoring function, therPalabras claves:BCR TKA, Gait symmetry, Knee Osteoarthritis, Total knee arthroplastyAutores:Kwon Y.M., Paul Arauz, Peng Y.Fuentes:scopusSensitivity and Specificity of Metal Ion Level in Pbkp_redicting Adverse Local Tissue Reactions Due to Head-Neck Taper Corrosion in Primary Metal-on-Polyethylene Total Hip Arthroplasty
ArticleAbstract: Background: There is increasing concern regarding the occurrence of adverse local tissue reactions (Palabras claves:adverse local tissue reaction, cobalt and chromium metal ion level, head-neck taper corrosion, metal-on-polyethylene total hip arthroplasty, pseudotumor pbkp_redictionAutores:Kwon Y.M., MacAuliffe J., Paul Arauz, Peng Y.Fuentes:scopusRisk Factors Associated With Early Complications of Revision Surgery for Head-Neck Taper Corrosion in Metal-on-Polyethylene Total Hip Arthroplasty
ArticleAbstract: Background: Adverse local tissue reactions (ALTRs) due to tribocorrosion of head-neck taper junctionPalabras claves:adverse local tissue reaction, complications, head-neck taper corrosion, metal-on-polyethylene total hip arthroplasty, revision surgery, RISK FACTORSAutores:Kwon Y.M., MacAuliffe J., Paul Arauz, Peng Y., Rossi D.Fuentes:scopus