Mostrando 10 resultados de: 15
Filtros aplicados
Subtipo de publicación
Article(15)
Publisher
Journal of Arthroplasty(3)
Journal of Orthopaedic Research(3)
Journal of Biomechanics(2)
Journal of Knee Surgery(2)
Bone and Joint Journal(1)
Computational modeling of polyethylene wear in total hip arthroplasty using patient-specific kinematics-coupled finite element analysis
ArticleAbstract: Computational modeling of polyethylene wear based on patient-specific gait kinematics and componentPalabras claves:component orientation, Finite Element Method, In-vivo kinematics, Polyethylene wearAutores:An S., Kwon Y.M., Paul Arauz, Peng Y.Fuentes:scopusBi-Cruciate Retaining Total Knee Arthroplasty Does Not Restore Native Tibiofemoral Articular Contact Kinematics During Gait
ArticleAbstract: Bi-cruciate retaining (BCR) total knee arthroplasty (TKA) design preserves both anterior and posteriPalabras claves:6-DOF, articular contact, Bi-cruciate retaining total knee arthroplasty, gait, in vivo kinematicsAutores:Klemt C., Kwon Y.M., Li G., Liow M.H.L., Paul Arauz, Peng Y., Tsai T.Y.Fuentes:scopusGender-specific difference of in-vivo kinematics in patients with unilateral total hip arthroplasty
ArticleAbstract: Purpose: Asymmetric gait patterns are known to persist in patients with unilateral total hip arthropPalabras claves:asymmetry, gait, gender, Kinematics, misalignment, total hip arthroplastyAutores:Kwon Y.M., Paul Arauz, Peng Y.Fuentes:scopusDoes Component Alignment Affect Patient Reported Outcomes following Bicruciate Retaining Total Knee Arthroplasty? An in Vivo Three-Dimensional Analysis
ArticleAbstract: This is an experimental study. Anterior cruciate ligament (ACL) and posterior cruciate ligament (PCLPalabras claves:bicruciate retaining total knee arthroplasty, Knee Society score, tibial component alignment, tibial slopeAutores:An S., Klemt C., Kwon Y.M., Limmahakhun S., Paul Arauz, Peng Y.Fuentes:scopusIn Vitro Kinematic Analysis of Single Axis Radius Posterior-Substituting Total Knee Arthroplasty
ArticleAbstract: This is an experimental study. As current posterior-substituting (PS) total knee arthroplasties havePalabras claves:Force, Kinematics, medial and lateral collateral ligaments, posterior-substituting total knee arthroplastyAutores:Castillo T., Klemt C., Kwon Y.M., Paul Arauz, Peng Y.Fuentes:scopusIn vivo kinematic analysis of patients with robotic-assisted total hip arthroplasty during gait at 1-year follow-up
ArticleAbstract: Background: Suboptimal component positioning has been suggested as an important contributing factorPalabras claves:asymmetry, component positioning, gait, Kinematics, robotic arm–assisted surgery, total hip arthroplastyAutores:Byers A., Desai P., Klemt C., Kwon Y.M., Paul Arauz, Peng Y.Fuentes:scopusIn vivo kinematics of deep lunges and sit-to-stand activities in patients with bicruciate-retaining total knee arthroplasty
ArticleAbstract: Aims The removal of the cruciate ligaments in total knee arthroplasty (TKA) has been suggested as aPalabras claves:Autores:Klemt C., Kwon Y.M., Paul Arauz, Peng Y.Fuentes:scopusIn vivo sliding distance on the metal-on-polyethylene total hip arthroplasty articulation using patient-specific gait analysis
ArticleAbstract: Metal-on-polyethylene (MoP) is the most commonly used bearing surface in primary total hip arthroplaPalabras claves:cross-shear, gait, metal-on-polyethylene total hip arthroplasty, Principal Component Analysis, Sliding distanceAutores:An S., Kwon Y.M., Paul Arauz, Peng Y.Fuentes:scopusIn-vivo 3-Dimensional gait symmetry analysis in patients with bilateral total hip arthroplasty
ArticleAbstract: Although three-dimensional (3D) asymmetry has been reported in unilateral THA patients during gait,Palabras claves:asymmetry, Bilateral total hip arthroplasty, component positioning, gait, KinematicsAutores:Kwon Y.M., MacAuliffe J., Paul Arauz, Peng Y.Fuentes:scopusIn-vivo analysis of sliding distance and cross-shear in Bi-cruciate retaining total knee arthroplasty
ArticleAbstract: Polyethylene remains the most popular bearing material for total knee arthroplasty (TKA). Despite itPalabras claves:Bi-cruciate retaining total knee arthroplasty, cross-shear, gait, In-vivo kinematics, Sliding distance, WearAutores:An S., Kwon Y.M., Paul Arauz, Peng Y.Fuentes:scopus