Mostrando 10 resultados de: 12
Publisher
Applied Mechanics and Materials(3)
Revista Cubana de Investigaciones Biomedicas(3)
International Journal of Electrochemical Science(2)
ECS Transactions(1)
Materials Research Society Symposium Proceedings(1)
Área temáticas
Física aplicada(5)
Medicina y salud(5)
Ingeniería y operaciones afines(4)
Cirugía y especialidades médicas afines(3)
Enfermedades(2)
Objetivos de Desarrollo Sostenible
ODS 3: Salud y bienestar(10)
ODS 9: Industria, innovación e infraestructura(8)
ODS 10: Reducción de las desigualdades(6)
ODS 12: Producción y consumo responsables(4)
ODS 11: Ciudades y comunidades sostenibles(2)
Origen
scopus(12)
Characterization and corrosion behavior of multilayer [TiN/TiCN]n growth on AISI 316LVM steel
Conference ObjectAbstract: In this paper a study of the corrosion resistance is shown in a physiological medium of multilayer cPalabras claves:Biomaterials, Hanks solution, Stainless steel AISI 316 LVM, [TiN/TiCN]nAutores:Ruíz E., Torres M.P., William Arnulfo Ch AperadorFuentes:scopusComputer vision technology on biomechanical diagnosis
Conference ObjectAbstract: Biomechanical diagnosis systems consists of movement capture equipment based on infrared cameras thaPalabras claves:artificial vision, Biomechanical diagnosis systems, Medical diagnosis for pathologies of movementAutores:Avilés O., Torres M.P., William Arnulfo Ch AperadorFuentes:scopusDesign of an active orthosis for prolonged surgery
ArticleAbstract: Remaining in a static position for a long time is damaging to health, due to the effort made by lowePalabras claves:active orthosis, Bioengineering, Exoskeleton, Skeletal muscle systemsAutores:Cifuentes Bernal A., Torres M.P., William Arnulfo Ch AperadorFuentes:scopusImproved protection against corrosion of galvanized steel embedded in alkali-activated concrete
ArticleAbstract: This research evaluates the corrosion resistance of a galvanic steel bar embedded in an alkali-activPalabras claves:Alkali-activated concrete, CORROSIÓN, Galvanized steelAutores:Delgado-Tobón A., Torres M.P., William Arnulfo Ch AperadorFuentes:scopusImproving electrochemical properties of [TiC(N)/TiNb(CN)]n multilayer films obtained on 316l stainless steel for biomedical applications
ArticleAbstract: In this work, a [TiC(N)/TiNb(CN)]n multilayer film was deposited using a multi-target magnetron sputPalabras claves:Biocompatible, CORROSIÓN, Multilayer coatingsAutores:Delgado-Tobón A., Torres M.P., William Arnulfo Ch AperadorFuentes:scopusTechnology in locomotion and domotic control for quadriplegic
Conference ObjectAbstract: The electronic control technology for mobility and domotics control (home automation systems) can bePalabras claves:Autores:Avilés O., Torres M.P., William Arnulfo Ch AperadorFuentes:scopusThermal vision system as a walking aid for blind and mobility-impaired persons
ArticleAbstract: The project describes the invention patent (Resolution 78032) of a thermal system informing a blindPalabras claves:artificial vision, Autonomy, Domotic control, Mobility impairment, Thermal panelAutores:Cifuentes Bernal A., Torres M.P., William Arnulfo Ch AperadorFuentes:scopusNew materials for reduction of corrosion levels
ArticleAbstract: Introduction: two million people worldwide suffer from arthritis or accident traumas and they are suPalabras claves:Biomaterials, coatings, Hip replacement, Knee replacement, ProsthesisAutores:Torres M.P., William Arnulfo Ch AperadorFuentes:scopusSelf-mobility system design for paraplegic patients
Conference ObjectAbstract: Tumors of the distal and proximal femur are treated by total femur resection. A hip disarticulationPalabras claves:Autores:Torres M.P., William Arnulfo Ch AperadorFuentes:scopusSensor design and new material for an intelligent system for people with musculoskeletal tension problems
Conference ObjectAbstract: The purpose of the current research is the use of new materials and sensors for the Design supportsPalabras claves:Autores:Cifuentes A., Torres M.P., William Arnulfo Ch AperadorFuentes:scopus