Echocardiographic evaluation of hemodynamics in patients with systolic heart failure supported by a continuous-flow LVAD


Abstract:

BACKGROUND: Hemodynamics assessment is important for detecting and treating post-implant residual heart failure, but its accuracy is unverified in patients with continuous-flow left ventricular assist devices (CF-LVADs).OBJECTIVES: We determined whether Doppler and 2-dimensional transthoracic echocardiography reliably assess hemodynamics in patients supported with CF-LVADs.METHODS: Simultaneous echocardiography and right heart catheterization were prospectively performed in 50 consecutive patients supported by using the HeartMate II CF-LVAD at baseline pump speeds. The first 40 patients were assessed to determine the accuracy of Doppler and 2-dimensional echocardiography parameters to estimate hemodynamics and to derive a diagnostic algorithm for discrimination between mean pulmonary capillary wedge pressure ≤15 versus >15 mm Hg. Ten patients served as a validation cohort.RESULTS: Doppler echocardiographic and invasive measures of mean right atrial pressure (RAP) (r = 0.863; p < 0.0001), systolic pulmonary artery pressure (sPAP) (r=0.880; p<0.0001), right ventricular outflowtract stroke volume (r=0.660; p < 0.0001), and pulmonary vascular resistance (r = 0.643; p = 0.001) correlated significantly. Several parameters, including mitral ratio of the early to late ventricular filling velocities >2, RAP >10 mm Hg, sPAP >40 mm Hg, left atrial volume index >33 ml/m<sup>2</sup>, ratio of mitral inflow early diastolic filling peak velocity to early diastolic mitral annular velocity >14, and pulmonary vascular resistance >2.5 Wood units, accurately identified patients with pulmonary capillary wedge pressure >15 mm Hg (area under the curve: 0.73 to 0.98). An algorithm integrating mitral inflow velocities, RAP, sPAP, and left atrial volume index was90%accurate in distinguishing normal from elevated left ventricular filling pressures.CONCLUSIONS: Doppler echocardiography accurately estimated intracardiac hemodynamics in these patients supported with CF-LVAD. Our algorithm reliably distinguished normal from elevated left ventricular filling pressures.

Año de publicación:

2014

Keywords:

  • Heart Failure
  • assist device
  • left ventricular
  • Echocardiography
  • Doppler
  • Hemodynamics

Fuente:

scopusscopus

Tipo de documento:

Article

Estado:

Acceso abierto

Áreas de conocimiento:

  • Enfermedad cardiovascular

Áreas temáticas de Dewey:

  • Fisiología humana
  • Enfermedades
  • Cirugía y especialidades médicas afines
Procesado con IAProcesado con IA

Objetivos de Desarrollo Sostenible:

  • ODS 3: Salud y bienestar
  • ODS 10: Reducción de las desigualdades
  • ODS 9: Industria, innovación e infraestructura
Procesado con IAProcesado con IA