Energy control and size optimization of a hybrid system (photovoltaic-hidrokinetic) using various storage technologies


Abstract:

This study analyzes the effects of different storage technologies on a hybrid renewable energy system composed of photovoltaic, hydrokinetic and diesel generator. Five types of storage are considered: lead acid, lithium ion, vanadium redox flow, hydrogen and hydrogen-vanadium redox flow. The analysis is mainly based on indicators such as Net Present Cost, Cost of Energy, unmet load and CO2 emissions. HOMER software has been used in this paper with time-sampling models and sensitivity studies to determine the effects of each storage system. The results show that the vanadium redox flow batteries system presents a lower net present cost and cost of energy. The sensitivity analysis shows that the vanadium redox flow system presents a greater variation of the minimum state of charge (SOC) in relation to the net present cost. However, the system composed of hydrogen and fuel cell present the lowest variation. The two proposed strategies for energy control show the same performance. However, when using the Load Tracking Control, the variation of the minimum state of charge with respect to the net cost is greater than the variation obtained when applying the Load Cycle Control.

Año de publicación:

2020

Keywords:

  • STORAGE
  • RENEWABLE ENERGY
  • Hybrid system
  • Hydrokinetic turbine

Fuente:

googlegoogle
scopusscopus

Tipo de documento:

Review

Estado:

Acceso restringido

Áreas de conocimiento:

  • Energía renovable
  • Energía renovable
  • Energía

Áreas temáticas:

  • Física aplicada