An evaluation method for voltage dips in a shipboard microgrid under quasi-balanced and unbalanced voltage conditions


Abstract:

High power motor loads are widely used in shipboard microgrids (SMGs) consuming about 70% of the generated electrical power. Voltage dips, which are usually caused by the starting current of high-power motors, are one of the main causes of onboard sensitive electrical equipment dropout. This phenomenon must be considered in design of SMGs to comply with maritime standards. In this paper, an evaluation method is proposed to estimate the expected severity of voltage dips and also generator current transient surges due to the onboard motor startups under real sea-going conditions. This is based on the Riemann-summation-principle evaluation method. The quasi-balanced and unbalanced ac bus voltage cases are carefully selected to present the actual impact of the voltage dips in real SMG. The evaluations are validated by measurements gathered from the ballast pump motor startup in the SMG. The …

Año de publicación:

2018

Keywords:

    Fuente:

    googlegoogle

    Tipo de documento:

    Other

    Estado:

    Acceso abierto

    Áreas de conocimiento:

      Áreas temáticas:

      • Física aplicada
      • Otras ramas de la ingeniería