Analysis of structure with dissipator spectra under design and control


Abstract:

The structures of Quito, Ecuador, are designed for the spectrum of the Ecuadorian code of 2015, or using the study of microzoning of the city of 2012. These spectra consider in general the effect of the blind reverse faults belonging to the city area. In this article, it is pointed out the importance of checking the design for the deterministic control spectra developed for Quito in 2015 based on earthquakes simulated in the blinds faults. In this paper we considered two models of extended plasticity for the structural elements and one model of plasticity for the ADAS and TADAS devices. Then, the technique of multimodal pushover is described, as well as the method of the capacity spectrum used to calculate the performance point of the structure. This structure was initially calculated by using design spectra and it had to be reinforced with ADAS devices in order to avoid its collapse for the control spectrum which has higher ordinates than the design one.

Año de publicación:

2017

Keywords:

  • Energy Dissipator
  • Design and control spectrum
  • Multimodal Pushover

Fuente:

scopusscopus
googlegoogle

Tipo de documento:

Article

Estado:

Acceso abierto

Áreas de conocimiento:

  • Ingeniería estructural
  • Matemáticas aplicadas

Áreas temáticas:

  • Ingeniería y operaciones afines
  • Física aplicada
  • Otras ramas de la ingeniería