Analysis of the thermodynamic performance of a solar-assisted heat pump using a condenser with recirculation.


Abstract:

English This research studied a direct-expansion solarassisted heat pump with a water recirculation system. The installed heat exchangers were a copper collector/evaporator of 0.75 m2 and a coil condenser built in copper pipe with a length of 2.49 m and 8 turns, submerged in a tank with 5 liters of water. It was used a centrifuge pump of 20 L/min at 110 V was used for the water recirculation. The installed compressor is a variable speed one at 12-24 V DC that uses R600a as working fluid. The throttling device installed was an electronic expansion valve. The experimental tests were carried out for a water recirculation setup and without recirculation, considering similar weather conditions. In this manner, it can be determined which configuration gives a higher performance to the system. To obtain data about incident solar radiation, wind speed and ambient temperature, a WS-1201 climatological station was …

Año de publicación:

2020

Keywords:

    Fuente:

    googlegoogle

    Tipo de documento:

    Other

    Estado:

    Acceso abierto

    Áreas de conocimiento:

    • Energía renovable
    • Energía

    Áreas temáticas:

    • Física aplicada

    Contribuidores: