Inter-subject variability in human atrial action potential in sinus rhythm versus chronic atrial fibrillation
Abstract:
Aims: Human atrial electrophysiology exhibits high inter-subject variability in both sinus rhythm (SR) and chronic atrial fibrillation (cAF) patients. Variability is however rarely investigated in experimental and theoretical electrophysiological studies, thus hampering the understanding of its underlying causes but also its implications in explaining differences in the response to disease and treatment. In our study, we aim at investigating the ability of populations of human atrial cell models to capture the inter-subject variability in action potential (AP) recorded in 363 patients both under SR and cAF conditions. Methods and Results: Human AP recordings in atrial trabeculae (n = 469) from SR and cAF patients were used to calibrate populations of computational SR and cAF atrial AP models. Three populations of over 2000 sampled models were generated, based on three different human atrial AP models. Experimental calibration selected populations of AP models yielding AP with morphology and duration in range with experimental recordings. Populations using the three original models can mimic variability in experimental AP in both SR and cAF, with median conductance values in SR for most ionic currents deviating less than 30% from their original peak values. All cAF populations show similar variations in G<inf>K1</inf>, G<inf>Kur</inf> and G<inf>to</inf>, consistent with AF-related remodeling as reported in experiments. In all SR and cAF model populations, inter-subject variability in I<inf>K1</inf> and I<inf>NaK</inf> underlies variability in APD<inf>90</inf>, variability in I<inf>Kur</inf>, I<inf>CaL</inf> and I<inf>NaK</inf> modulates variability in APD<inf>50</inf> and combined variability in I<inf>to</inf> and I<inf>Kur</inf> determines variability in APD<inf>20</inf>. The large variability in human atrial AP triangulation is mostly determined by I<inf>K1</inf> and either I<inf>NaK</inf> or I<inf>NaCa</inf> depending on the model. Conclusion: Experimentally- calibrated human atrial AP models populations mimic AP variability in SR and cAF patient recordings, and identify potential ionic determinants of inter-subject variability in human atrial AP duration and morphology in SR versus cAF. © 2014 Sánchez et al.
Año de publicación:
2014
Keywords:
Fuente:
Tipo de documento:
Article
Estado:
Acceso abierto
Áreas de conocimiento:
- Enfermedad cardiovascular
- Fisiología
Áreas temáticas:
- Fisiología humana
- Enfermedades