Ischemia detection from morphological QRS angle changes


Abstract:

In this paper, an ischemia detector is presented based on the analysis of QRS-derived angles. The detector has been developed by modeling ischemic effects on the QRS angles as a gradual change with a certain transition time and assuming a Laplacian additive modeling error contaminating the angle series. Both standard and non-standard leads were used for analysis. Non-standard leads were obtained by applying the PCA technique over specific lead subsets to represent different potential locations of the ischemic zone. The performance of the proposed detector was tested over a population of 79 patients undergoing percutaneous coronary intervention in one of the major coronary arteries (LAD (n = 25), RCA (n = 16) and LCX (n = 38)). The best detection performance, obtained for standard ECG leads, was achieved in the LAD group with values of sensitivity and specificity of , , followed by the RCA group with , Sp = 94.4 and the LCX group with , , notably outperforming detection based on the ST series in all cases, with the same detector structure. The timing of the detected ischemic events ranged from 30 s up to 150 s (mean = 66.8 s) following the start of occlusion. We conclude that changes in the QRS angles can be used to detect acute myocardial ischemia.

Año de publicación:

2016

Keywords:

  • Laplacian noise
  • PCI
  • myocardial ischemia
  • QRS angles

Fuente:

scopusscopus

Tipo de documento:

Article

Estado:

Acceso restringido

Áreas de conocimiento:

  • Enfermedad cardiovascular

Áreas temáticas:

  • Enfermedades
  • Fisiología humana