Long-Term Results of Everolimus-Eluting Stents Versus Drug-Eluting Balloons in Patients With Bare-Metal In-Stent Restenosis: 3-Year Follow-Up of the RIBS V Clinical Trial
Abstract:
Objectives The aim of this study was to compare the long-term efficacy of everolimus-eluting stents (EES) and drug-eluting balloons (DEB) in patients with bare-metal stent in-stent restenosis (ISR). Background The relative long-term clinical efficacy of current therapeutic modalities in patients with ISR remains unknown. Methods The 3-year clinical follow-up (pre-specified endpoint) of patients included in the RIBS V (Restenosis Intra-Stent of Bare-Metal Stents: Drug-Eluting Balloon vs Everolimus-Eluting Stent Implantation) randomized clinical trial was analyzed. All patients were followed yearly using a pre-defined structured questionnaire. Results A total of 189 patients with bare-metal stent ISR were allocated to either EES (n = 94) or DEB (n = 95). Clinical follow-up at 1, 2, and 3 years was obtained in all patients (100%). Compared with patients treated with DEB, those treated with EES obtained better angiographic results, including larger minimal luminal diameter at follow-up (primary study endpoint; 2.36 ± 0.6 mm vs. 2.01 ± 0.6 mm; p < 0.001). At 3 years, the rates of cardiac death (2% vs. 1%), myocardial infarction (4% vs. 5%) and target vessel revascularization (9% vs. 5%) were similar in the DEB and EES arms. Importantly, however, at 3 years, the rate of target lesion revascularization was significantly lower in the EES arm (2% vs. 8%; p = 0.04; hazard ratio: 0.23; 95% confidence interval: 0.06 to 0.93). The need for “late” (>1 year) target vessel (3 [3.2%] vs. 3 [3.2%]; p = 0.95) and target lesion (1 [1%] vs. 2 [2.1%]; p = 0.54) revascularization was low and similar in the 2 arms. Rates of definite or probable stent thrombosis (1% vs. 0%) were also similar in the 2 arms. Conclusions The 3-year clinical follow-up of the RIBS V clinical trial confirms the sustained safety and efficacy of EES and DEB in patients treated for bare-metal stent ISR. In this setting, EES reduce the need for target lesion revascularization at very long-term follow-up. (RIBS V [Restenosis Intra-Stent of Bare Metal Stents: Paclitaxel-Eluting Balloon vs Everolimus-Eluting Stent] [RIBS V]; NCT01239953)
Año de publicación:
2016
Keywords:
- everolimus-eluting stent(s)
- in-stent restenosis
- drug-eluting stent(s)
- drug-eluting balloon(s)
Fuente:

Tipo de documento:
Article
Estado:
Acceso abierto
Áreas de conocimiento:
- Enfermedad cardiovascular
- Medicina interna
Áreas temáticas:
- Medicina forense; incidencia de enfermedades
- Enfermedades
- Cirugía y especialidades médicas afines