New diagnostic developments for intense ion beam measurements on PBFA II
Abstract:
A new diagnostic package has been developed for the Sandia National Laboratories' PBFA-II accelerator. The package—which emphasizes off-axis Rutherford-scattering measurements—includes the following: off- and on-axis multi-frame dE/dx ion pinhole cameras, an off-axis energy-resolved ion movie camera, an on-axis time-resolved ion movie camera, an off- or on-axis time-resolved Rutherford magnetic spectrograph which has a one-dimensional imaging capability, time-integrated and time-resolved Kα X-ray pinhole cameras, a plasma visible spectroscopy diagnostic, an elliptical crystal spectrograph, and a high bandwidth transient data recording system based on fiber-optic and streak camera technology. Additionally, several other new diagnostic systems are currently under development. These consist of an ultra-fast X-ray framing camera based on sealed MCP imaging tubes, a time-resolved Kα X-ray …
Año de publicación:
1990
Keywords:
Fuente:

Tipo de documento:
Other
Estado:
Acceso abierto
Áreas de conocimiento:
- Física de partículas
Áreas temáticas de Dewey:
- Física aplicada
- Magnetismo
- Electricidad y electrónica