Performance analysis of filters used in Three-Phase Controlled Rectifiers of wind power systems


Abstract:

This paper presents a performance analysis of L and LCL filters used in Pulse With Modulated Three-Phase Controlled Rectifiers of Wind Power Systems. The rectifier is modeled with both filters using PWM-switch model in order to obtain a dc equivalent circuit. This method consists of replacing the nonlinear part by a linear equivalent circuit composed of dependent sources so that the analysis is easier. The methodology presented is very similar to linear amplifier circuit analysis whereby the transistor is replaced by its equivalent circuit model. The advantage of this model is that it permits to simulate the rectifier behavior without using any control, such that anyone can use simple linear electronic circuit analysis programs. The switch duty ratios are calculated from the dc circuit. Moreover, the rectifier is simulated in open loop and using a sinusoidal PWM to verify which filter is better in terms of Total Harmonic Distortion and efficiency.

Año de publicación:

2015

Keywords:

  • Total harmonic distortion
  • Three-Phase Controlled Rectifier
  • Wind Power System

Fuente:

scopusscopus
rraaerraae

Tipo de documento:

Conference Object

Estado:

Acceso restringido

Áreas de conocimiento:

  • Energía

Áreas temáticas:

  • Física aplicada
  • Otras ramas de la ingeniería