Shear capacity equation for channel shear connectors in steel-concrete composite beams


Abstract:

In this research the effect of high strength concrete (HSC) on shear capability of the channel shear connectors (CSC) in the steel concrete composite floor system was estimated experimentally and analytically. The push-out test was carried out for assessing the accurateness of the proposed model (nonlinear and finite element model) for the test specimens. A parametric analysis was conducted for pbkp_redicting the shear capacity of the connectors (CSC) in the HSC. Eight push-out specimens of different sizes with different strength levels were tested under the monotonic loading system. The aim of this study was to evaluate the efficacy of the National Building Code of Canada (NBC) of Canada for analysing the loading abilities of the CSC in the HSC. Using the experimental tests results and verifying the finite element results with them, it was then confirmed by the extended parametric studies that the Canadian Design Code was less efficient for pbkp_redicting the capacity of the CSC in the HSC. Hence, an alternative equation was formulated for pbkp_redicting the shear capacity of these connectors during the inclusion of HSC for designing the codes.

Año de publicación:

2018

Keywords:

  • Push-out test
  • Steel concrete composite floor
  • High strength concrete
  • finite element analysis
  • Channel shear connector

Fuente:

scopusscopus
googlegoogle

Tipo de documento:

Article

Estado:

Acceso restringido

Áreas de conocimiento:

  • Ingeniería estructural

Áreas temáticas:

  • Ingeniería civil