Sizing methods for stand-alone hybrid systems based on renewable energies and hydrogen


Abstract:

This paper presents a comparative study of four sizing methods for a stand-alone hybrid generation system integrating renewable energies (photovoltaic panels and wind turbine) and backup and storage system based on battery and hydrogen (fuel cell, electrolyzer and hydrogen storage tank). Two of them perform a technical sizing. In one case, the sizing is based on basic equations, and in the other case, an optimal technical sizing is achieved by using Simulink Design Optimization. The other two methods perform an optimal techno-economical sizing by using the hybrid system optimization software HOMER and HOGA, respectively. © 2012 IEEE.

Año de publicación:

2012

Keywords:

    Fuente:

    scopusscopus

    Tipo de documento:

    Conference Object

    Estado:

    Acceso restringido

    Áreas de conocimiento:

    • Energía renovable
    • Energía renovable

    Áreas temáticas:

    • Física aplicada