Sensor- and equation-based sit-to-stand power: The effect of age and functional limitations
Abstract:
Estimating lower-limb muscle power during sit-to-stand (STS) tests is feasible for large-scale implementation. This study investigated 1) whether age, functional limitations and sex have an influence on the movement strategy and power production during STS; and 2) potential differences between STS power estimated with either a simple equation or a sensor. Five-repetition STS data of 649 subjects (♂352 ♀297) aged 19 to 93 years were included. Subjects were divided in different age groups and levels of functioning. A body-fixed sensor measured (sub)durations, trunk movement (flexion/extension) and STS muscle power (P<inf>sensor</inf>). Additionally, mean STS muscle power was calculated by a mathematic equation (Alcazar et al., 2018b)P<inf>formula</inf>.Results revealed that 1) older subjects and women showed greater trunk flexion before standing up than younger subjects and men, respectively (both p < 0.001); 2) well-functioning adults seemed to have the tendency to not extend the trunk fully during the sit-to-stand transition (mean difference extension – flexion range = −15.3° to −13.1°, p < 0.001); 3) mobility-limited older adults spent more time in the static sitting and standing positions than their well-functioning counterparts (all p < 0.001); 4) STS power decreased with age and was lower in women and in limited-functioning subjects compared to men and well-functioning subjects, respectively (p < 0.05); 5) P<inf>formula</inf> was highly related to P<inf>sensor</inf> (ICC = 0.902, p < 0.001); and 6) P<inf>formula</inf> demonstrated higher values than P<inf>sensor</inf> in well-functioning adults [mean difference = −0.31 W/kg and −0.22 W/kg for men and women, respectively (p < 0.001)], but not among limited-functioning older adults. To conclude, this study showed that age and functional limitations have an influence on the movement strategy during a 5-repetition STS test. Differences in movement strategy can affect the comparison between P<inf>formula</inf> and P<inf>sensor</inf>. In well-functioning older adults, P<inf>formula</inf> was slightly higher than P<inf>sensor</inf>, which might be related to an incomplete extension in the sit-to-stand transition.
Año de publicación:
2023
Keywords:
- aging
- Chair rise
- Functional capacity
- inertial measurement unit
- Lower-limb muscle power
Fuente:
scopusTipo de documento:
Article
Estado:
Acceso restringido
Áreas de conocimiento:
- Fisioterapia
- Factores humanos y ergonomía
- Medicina interna
Áreas temáticas de Dewey:
- Fisiología humana
- Cirugía y especialidades médicas afines
- Ginecología, obstetricia, pediatría, geriatría
Objetivos de Desarrollo Sostenible:
- ODS 5: Igualdad de género
- ODS 16: Paz, justicia e instituciones sólidas
- ODS 3: Salud y bienestar