Automatic detection of ST-T complex changes on the ECG using filtered RMS difference series: Application to ambulatory ischemia monitoring
Abstract:
A new detector is presented which finds changes in the repolarization phase (ST-T complex) of the cardiac cycle. It operates by applying a detection algorithm to the filtered root mean square (rms) series of differences between the beat segment (ST segment or ST-T complex) and an average pattern segment. The detector has been validated using the European ST-T database, which contains ST-T complex episodes manually annotated by cardiologists, resulting in sensitivity/positive pbkp_redictivity of 85/86%, and 85/76%, for ST segment deviations and ST-T complex changes, respectively. The proposed detector has a performance similar to those which have a more complicated structure. The detector has the advantage of finding both ST segment deviations and entire ST-T complex changes thereby providing a wider characterization of the potential ischemic events. A post-processing stage, based on a cross-correlation analysis for the episodes in the rms series, is presented. With this stage subclinical events with repetitive pattern were found in around 20% of the recordings and improved the performance to 90/85%, and 89/76%, for ST segment and ST-T complex changes, respectively.
Año de publicación:
2000
Keywords:
- eCG
- Automatic ischemia detection
- ST-T complex changes
- ST segment deviations
Fuente:
Tipo de documento:
Article
Estado:
Acceso restringido
Áreas de conocimiento:
- Enfermedad cardiovascular
- Simulación por computadora
Áreas temáticas:
- Farmacología y terapéutica
- Fisiología humana
- Enfermedades