Caracterización del IHX en un sistema de refrigeración automotriz y el COP con refrigerante R134A


Abstract:

The present work has the objective of characterizing several coaxial heat exchanger geometries in an automotive cooling system and its effect on the performance coefficient, using R-134a as refrigerant by means of experimental tests. In the first instance, the experimental tests were carried out with different geometries of coaxial interchanges involved in the high-pressure line between the condenser and the expansion valve, as well as the low pressure line between the evaporator and the compressor, Between the volume of the exchanger and the coefficient of performance by means of a multifactorial analysis. The development of the research entails complying with parameters for the acquisition of experimental data and the development of an adequate experimental design. Statistical regressions were developed with R2 of 86.86% and a standard deviation of 2.2 for the low-pressure zone, while for the high pressure zone The regression determined a R2 of 95.17% and a standard deviation of 0.57. As for the COP and the T variables is statistically significant with a value of R2 of 99.97%, thus helping to design the heat exchangers to decrease fuel consumption in vehicles.

Año de publicación:

2017

Keywords:

    Fuente:

    googlegoogle

    Tipo de documento:

    Other

    Estado:

    Acceso abierto

    Áreas de conocimiento:

      Áreas temáticas:

      • Física aplicada
      • Otras ramas de la ingeniería