A survey of testing and monitoring methods for stator insulation systems in induction machines
Abstract:
A breakdown of the electrical insulation system causes catastrophic failure of the electrical machine and brings large process downtime losses. To determine the conditions of the stator insulation system of motor drive systems, various testing and monitoring methods have been developed. This paper presents an in-depth literature review of more than 20 existing methods, including the most common methods to assess the phase-to-ground, phase-to-phase, and turn-to-turn insulation conditions. The methods are categorized into as online and offline methods, each of which are further grouped into specific areas according to their physical nature. The paper focuses on turn-toturn insulation testing and monitoring of low-voltage machines, which is a rapidly expanding area for both research and product development efforts. Finally, a new approach to online monitoring of turn-to-turn insulation faults for low-voltage induction motors is recommended. ©2007 IEEE.
Año de publicación:
2008
Keywords:
- Partial discharge analysis
- Hydro-generator
- Phase resolved partial discharge measurement
- condition based maintenance
Fuente:
Tipo de documento:
Conference Object
Estado:
Acceso restringido
Áreas de conocimiento:
Áreas temáticas:
- Física aplicada