Mostrando 4 resultados de: 4
Filtros aplicados
Subtipo de publicación
Article(4)
Publisher
European Heart Journal(1)
JACC: Heart Failure(1)
Journal of Heart and Lung Transplantation(1)
Journal of the American College of Cardiology(1)
Área temáticas
Enfermedades(4)
Cirugía y especialidades médicas afines(2)
Medicina y salud(2)
Fisiología humana(1)
Origen
scopus(4)
A simplified echocardiographic technique for detecting continuous-flow left ventricular assist device malfunction due to pump thrombosis
ArticleAbstract: Background Malfunction of a continuous-flow left ventricular assist device (CF-LVAD) due to device tPalabras claves:cardiomyopathy, Echocardiography, Heart Failure, Left ventricular assist device, ThrombosisAutores:Andrea M. Cordero-Reyes, Bhimaraj A., Bruckner B.A., Chang S.M., Elias B., Estep J.D., Loebe M., Suarez E.E., Torre-Amione G., Trachtenberg B.H., Vivo R.P.Fuentes:scopusEchocardiographic evaluation of hemodynamics in patients with systolic heart failure supported by a continuous-flow LVAD
ArticleAbstract: BACKGROUND: Hemodynamics assessment is important for detecting and treating post-implant residual hePalabras claves:assist device, Doppler, Echocardiography, Heart Failure, Hemodynamics, left ventricularAutores:Andrea M. Cordero-Reyes, Ashrith G., Bhimaraj A., Bruckner B.A., Elias B., Estep J.D., Krim S.R., Loebe M., Nagueh S.F., Torre-Amione G., Trachtenberg B.H., Vivo R.P.Fuentes:scopusHigh proportion of patients with end-stage heart failure regardless of aetiology demonstrates anti-cardiac antibody deposition in failing myocardium: Humoral activation, a potential contributor of disease progression
ArticleAbstract: Aims Various reports have raised the possibility of humoral immune responses as contributors for thePalabras claves:Antibodies, ATP synthase, autoimmunity, Heart Failure, myocardiumAutores:Andrea M. Cordero-Reyes, Assad-Kottner C., Barrios R., Bhimaraj A., Estep J.D., Fernandez-Sada E., Flores-Arredondo J.H., Torre-Amione G., Trevino A.R., Youker K.A.Fuentes:scopusPercutaneous placement of an intra-aortic balloon pump in the left axillary/subclavian position provides safe, ambulatory long-term support as bridge to heart transplantation
ArticleAbstract: Objectives: This study evaluated the feasibility, tolerability, and efficacy of a strategy for percuPalabras claves:CXR, Heart Failure, Heart transplant, HF, IABP, Intra-aortic balloon pump, LVAD, OHT, Subclavian arteryAutores:Andrea M. Cordero-Reyes, Bhimaraj A., Bismuth J., Bruckner B.A., Estep J.D., Khalil N., Kleiman N.S., Loebe M., Orrego C.M., Torre-Amione G., Trachtenberg B.H.Fuentes:scopus