Detection of cavitation in centrifugal pump for vibration analysis


Abstract:

In the cavitation detection project in a centrifugal pump whose purpose was to detect the presence of the phenomenon through the analysis of vibration signals received by acceleration sensors and governed by the ISO 10816 standard of vibration severity, the signals were analyzed under the normal operation and cavitation regime. Determining the alabe pitch frequency (BPF) verifies an alteration in the vibration range since the cavities near the leading edge of the alabe appear periodically oscillating and their overall value or RMS when making a comparison under the two regimes is altered noticeably.

Año de publicación:

2018

Keywords:

  • alabe pitch frequency
  • cavitation vibration analysis
  • vibration severity
  • Centrifugal Pump

Fuente:

scopusscopus

Tipo de documento:

Conference Object

Estado:

Acceso restringido

Áreas de conocimiento:

  • Ingeniería mecánica
  • Ingeniería mecánica

Áreas temáticas:

  • Física aplicada
  • Ingeniería y operaciones afines