Use of threshold PEP with an adult non-rebreather oxygen mask plus prone positioning in acute hypoxemic respiratory failure due to SARS-CoV-2 infection during the collapse of the health system in a low-income country
Abstract:
During the coronavirus disease 2019 pandemic, Ecuador reported a collapse of the healthcare system, in which intensive care unit beds were lacking. Therefore, we sought to determine whether the use of threshold expiratory positive pressure with an adult non-rebreather oxygen mask plus prone positioning is useful for improving oxygenation. Twelve patients were included. Eight patients (66.7%) survived, while four patients (33.3%) died. Baseline arterial oxygen saturation (%) prior placement median (interquartile range) 85.5% (80%–89%) and arterial oxygen saturation (%) post placement of the device was median (interquartile range) (93%–96%) (P = 0.0001). Respiratory rate before placement was median (interquartile range) 38 (36–42) and post placement of the device was median (interquartile range) 24 (22–30) (P = 0.0005). The use of an adapted device might be useful for the management of acute hypoxemic respiratory failure due to severe acute respiratory syndrome coronavirus 2 pneumonia, particularly when mechanical ventilators and high-flow oxygen systems are unavailable.
Año de publicación:
2023
Keywords:
- Severe Acute Respiratory Syndrome Coronavirus 2
- Respiratory Distress Syndrome
- Intensive care units
- prone position
- adult
- Pandemics
- covid-19
Fuente:
Tipo de documento:
Article
Estado:
Acceso abierto
Áreas de conocimiento:
- Medicina interna
- Medicina interna
Áreas temáticas:
- Enfermedades
- Problemas sociales y servicios a grupos