Application of Strip Model to Edge Column-Slab Connections Loaded with Outward Eccentricity
Abstract:
The strip model describes a load path prior to failure that can be tailored to a wide range of slabs under concentrated loads, both concentric and eccentric. Eccentric punching shear can occur in concrete slab-column connections subjected to shear and unbalanced moment, such as edge and corner columns. This paper shows how the strip model is applied to experiments of edge column-slab connections tested with outward eccentricities, and compares this approach to the traditional and simplified ACI 318-19 approaches for dealing with eccentric punching shear. This work shows how a lower-bound plasticity-based model can be used for the practical case of the slab-column capacity for edge and corner columns, how it may explain the mechanics behind the ACI code provisions, and can help researchers identify adequate test setups for future experiments.
Año de publicación:
2022
Keywords:
- eccentric punching shear
- Slabs
- columns
- reinforced concrete
- arched strut
- strip model
Fuente:

Tipo de documento:
Conference Object
Estado:
Acceso restringido
Áreas de conocimiento:
- Ingeniería estructural
Áreas temáticas:
- Ingeniería civil
- Construcción de edificios
- Materiales y fines específicos